| Sign In | Join Free | My fnxradio.com |
|
Normal temperature Frequency Tolerance : ±10ppm
Frequency Stability : ±30ppm
Load Capacitance : 20pF
Operating Temperature : -40℃~+85℃
Frequency : 14.318MHz
Description : Crystal 14.318MHz ±10ppm 20pF SMD3225-4P
Mfr. Part # : 7U14318E20UCG
Model Number : 7U14318E20UCG
Package : SMD3225-4P
The Series 7U is a seam-sealed ceramic surface mount quartz crystal unit with a 3.2*2.5mm package. It is designed for various electronic applications requiring precise frequency control.
| Part Number (P/N SJK) | Output Frequency | Frequency Tolerance (@25C) | Load Capacitance (CL) | Operating Temperature Range | Storage Temperature Range | Shunt Capacitance (C0) | Equivalent Series Resistance (ESR) | Aging @25C (1st Year Max) |
| 7U14318E20UCG | 14.318180MHz | 10 ppm | 20.0 PF | -40 C to +85 C | -40 C to +125 C | 3.0 PF Max | 80 Max | 3ppm/year |
| No. | Test Item | Test Conditions | Standard Requirements |
| 1 | Drop | Free fall from 55cm height onto a wooden board, 3 times. | Frequency change within 5ppm, resistance change within 15% before and after test. |
| 2 | Vibration | Frequency: 10~55Hz, Amplitude: 1.5mm. Duration: 2 hours for each of the three directions (X, Y, Z). | Frequency change within 5ppm, resistance change within 15% before and after test. |
| 3 | Thermal Shock | 25 cycles of high and low temperature in a test chamber. Low temp: -403C for 30 min, High temp: 852C for 30 min. Transition time: 3 minutes between temperatures. | Frequency change within 5ppm, resistance change within 15% before and after test. |
| 4 | Hermeticity | Helium pressure: 50.5 Kg/cm, Helium pressurization time: 120 minutes. | Leak rate: 110-9 Pa.m/s |
| 5 | Resistance to Soldering Heat | Wave crest temperature: 260C10C, Time: 155 seconds. | Frequency change within 5ppm, resistance change within 15% before and after test. |
| 6 | Solderability Test | Temperature: 260C10C, Immersion time: 31 seconds. | Solder-covered area of the pins 90%. |
| 7 | High Temperature and High Humidity | Temperature: 60C2C, Humidity: 90%~95%, Duration: 240 hours. | 1. Frequency change within 5ppm, resistance change within 15% before and after test. 2. Product surface should not be rusted. |
| 8 | High Temperature Test | Temperature: 85C2C, Duration: 240 hours. | Frequency change within 5ppm, resistance change within 15% before and after test. |
| 9 | Low Temperature Test | Temperature: -40C2C, Duration: 240 hours. | Frequency change within 5ppm, resistance change within 15% before and after test. |
| 10 | Life Test | Voltage: 5V, Temperature: 25, Duration: 1000 hours. | Frequency change within 5ppm, resistance change within 15% before and after test. |
|
|
Quartz crystal unit SJK 7U14318E20UCG 3.2 by 2.5 millimeter ceramic surface mount for frequency control Images |